Included in our range are the following fire related hard-wired products:

or click for wired security systems and devices.
 

FIRE ALARM PANELS C-TEC Range
 

Within C- TEC's collection of conventional fire alarm control panels, you will find a panel to suit your requirements.


 
 

For ease of installation and maintenance the panels have a lift off lid and clear instructions adjacent to the wiring terminals. Common features include keyswitch operation, open & short circuit fault indication and true battery monitoring. The external control buttons on the front displays can only be accessed via the keyswitch and allow silencing of alarms, system resetting and evacuation procedures.

Line fault monitoring for detector removal is standard on the MFP range and is available for the EFP-l and FP panels with an optional electronic monitoring unit 

All C-TEC panels are fully compliant with BS 5839, Part 4. Should it be necessary, all panels are capable of reversion to the pre-1988 BS setting (no short circuit monitoring). 

The FP range is suitable for a variety of applications requiring multiple zones. Available in 2, 4 and 6 zone versions, the FP range incorporates zone isolation and a one man test facility.

FP Fire Alarm Control Panels

Ancillary connections for expansion modules allow the use of repeater panels, multiple sounder outputs, fault relays, connection to a landlord panel or the use of a class change input.

MFP Fire Alarm Control Panels

The MFP is a microprocessor based fire panel which perfectly balances features and pricing. The ability for cross connection with other panels makes the MFP ideal for upgrading or extending existing systems.

The MFP can easily be expanded from to 28 zones in 4 zone steps and allows the connection of up to 8 repeater panels to each system.

These offer full control with the exception of zone isolation. For added versatility, the panel is compatible with a variety of add-on boards for additional sounder circuits.

EFP-1 Fire Alarm Control Panels

The  EFP-l is an economical fire alarm control panel ideal for single zone applications such as factory units, shops etc. The basic panel can be easily enhanced by utilising the optional loom which allows a class change input and by employing additional RLP-l relays to provide latching fire and fault outputs. 
 

FIRE ALARM PANELS Fire Sense Range

The Fire Sense range of microprocessor based panels consists of Compact, Standard and System fire alarm control units. All fire panels consist of a sturdy powder coated steel box with a membrane front panel.

The front panels incorporate simple to understand LED indication of zone fire and fault conditions and all required resetting, testing and isolation controls. A universal keyswitch operation prevents unauthorized access to control buttons.

Other common features include built-in detector removal monitoring, zone isolation, zone monitoring for open & short circuit, class change facility and one man testing.

All Fire Sense panels are fully compliant with BS 5839, Part 4 1988  but are capable of reversion to the pre-1988 standard i.e. a short circuit generates fire condition. 

FIRE ALARM PANELS Fire Sense Range 

Compact Fire Alarm Control Panels

The Fire Sense Compact panels are ideal for smaller installations requiring system zoning. Available in 2 and 4 zone versions, the Compact panels can accommodate up to 40 and 80 detectors respectively. 

This highly featured, yet unobtrusive panel incorporates 2 fully monitored sounder circuits, open and short circuit zone monitoring, zone isolation and a one-man-test facility. By utilising the class change input and/or connection of a repeater panel, the system can be easily configured to meet your needs. 

Standard Fire Alarm Control Panels 

Standard panels are available with 4 and 8 zone coverage and incorporate 4 fully monitored sounder circuits. Zone and sounder isolation, zone one non latch and built-in detector removal monitoring are included within the panels numerous features. 

Auxiliary connections consist of two fire relays, one fault relay and a fully monitored class change input. A fully functional repeater panel is also available. 

System Fire Alarm Control Panels

Fire Sense System panels are available in 12 and 16 zone versions for use in large premises that require extensive zoning. The panels are designed to make these complex systems easy to install, operate and maintain. 

System panels incorporate zone and sounder isolation and if required, can provide a separate sounder circuit for each zone. Auxiliary connections consist of two fire relays and one fault relay. 

FIRE ALARM PANELS Morley ZX Range 

Morley ZX Addressable Fire Panels

The ZXa, ZXi and ZXMi are the latest analogue addressable fire panels from Morley Electronics. Expandable from 1-2, 1-3 and 1-5 loops respectively, the Morley ZX panels support all Apollo and Hochiki analogue/addressable protocols with the ZXa also supporting Nittan protocols. 

All ZX panels are fully compliant with BS 5839, part 4 (1988), European EMC legislation and bear the CE mark. 

System Operation 

System operation is made simple by the back-lit LCD main display, zonal fire and fault LED indicators. The panels have user friendly menu driven software features and an 'auto-learn' facility which can scan the system and provide the address and type of every connected device. To aid system administration every zone and device can be given a customized description. For security, the panels have dual level pass code protection and an internal memory lock to prevent unauthorized data entry. 

The sensor circuits for all panels are 2 wire analogue addressable loops, capable of supporting up to 126 devices along a maximum length of 1,250 metres. 

The 500 most recent system events (fire, fault, reset, etc.) are stored in an event log which can be viewed or printed at any time. The log stores a description of the event along with the time and, where applicable, the zone, address and analogue value of the device concerned. 

The ZXa has two programmable sounder outputs, while the ZXi and ZXMi have four. All panels provide two programmable auxiliary relays and full monitoring of external wiring for open or short circuits. 

CONVENTIONAL FIRE DETECTORS Apollo Series 60 
 

The Apollo Series 60 range of low profile conventional fire detectors provides answers for every environment and are compatible with most control panels. All the detectors in the range have the same external dimensions and feature an integral LED to give a visual indication of an alarm state. The mounting base does not contain any electronic parts which could be damaged during installation. 

The complete range is approved by FOC in the UK and Vds in Germany. The range has been manufactured to EN54 (BS5445) standard and the polycarbonate casing is VO rated to UL 94. 


Optical Smoke Detector

The Apollo Conventional Optical Smoke Detector consists of a pulsing LED situated in the centre of a labyrinth which excludes any other light source. A photo-diode is positioned at an angle to the LED so it does not register the light emitted. When smoke enters the labyrinth, it scatters the light which is then registered by the photo-diode. An alarm state is triggered if the following two pulses are also registered. 

To help prevent false alarms, the Series 60 Optical Smoke Detector contains a daylight filter shielding the photo-diode from external light that would trigger an alarm condition. 

Ionisation Smoke Detector

The Apollo Series 60 Ionisation Smoke Detector consists of an open outer chamber and a semi-sealed inner chamber with current flowing between them. When smoke enters the detector, it reduces the current flow in the outer chamber. This creates a voltage increase between the two chambers. The voltage is monitored by the electronic circuitry which triggers the alarm when it reaches a preset threshold. 

An integrating version of the Series 60 detector  is also available which requires smoke to be present at alarm levels for a period of twenty seconds before operating, therefore making it suitable for use in areas expecting transient, high levels of smoke. 

 Fixed Heat detector is available with preset temperature limits of 65°C or 75°C 

The Rise Heat detector contains two matching thermistors. One is exposed to the ambient temperature and the other is 
sealed. Normally, the two thermistors are at similar temperatures, but the heat from a fire will cause the temperature of the exposed thermistor to rise rapidly and trigger the detector alarm. In the Rate of Rise Heat detector the ratio of thermistor resistance is monitored electronically and the alarm is triggered if the ratio exceeds a preset value. These Rate of Rise 
detectors are designed to detect a fire as the temperature increases, but they also feature a fixed upper temperature safety limit of 60°C should the rate of rise in temperature be too slow. 

Apollo  Series 60 Mounting Base

The Series 60 Base  has been designed to allow easy fitting of all Apollo detectors using a one way only fit. 

A base fitted with a diode on line is available to allow conventional systems to operate correctly when one or more detectors have been removed. 

The series 60 relay base provides voltage free change over contacts. 
 

ANALOGUE ADDRESSABLE FIRE DETECTORS Apollo XP95 Series 

The Apollo XP95 series analogue addressable provides a high degree flexibility and reliability. 

Each device is uniquely identified by the control panel via a coded 'X-PERT' card. This card is inserted into the monitor base and provides simple and speedy installation while avoiding addressing errors. 

lonisation Smoke Monitor 

XP95 ionisation smoke monitor consists of an outer smoke chamber and a semi-sealed inner ionisation chamber. When smoke enters the ionisation chamber the current flowing through the chamber reduces and causes a voltage difference between the two chambers. This voltage difference is monitored by the sensor electronics which triggers an alarm condition. 

Optical Smoke Monitor 

The optical smoke monitor uses the same case as the ionisation monitor and is differentiated by the clear indicator LED. 

Inside the detector there is a diode producing infra-red light and a photo-diode. When smoke enters the monitor, the infra-red light is scattered causing it to be registered by the photo-diode and produce an alarm condition. 

Temperature Monitors

The XP95 fixed temperature heat monitors utilise a single thermistor network to provide a voltage proportional to the temperature of the outside air. Standard and high temperature versions are available which have thresholds of 55°C and 90°C respectively. 

The standard monitors temperature response allows for use as an EN54 grade 2 rate of rise heat detector. 

Manual Call Points 

Available in standard or weather- proof versions, XP95 manual call points utilise DIL addressing with the interrupt feature providing fast location reporting of the call point.

XP95 Isolator 

XP95 isolators located along the length of the detection loops will prevent a short circuit from completely disabling that loop. 

In the event of a short circuit only the section between isolators where the short circuit occurred will be disabled. When the short circuit has been repaired, the isolator will automatically restore the disabled section.

Also in stock Hochiki ASX range and Ziton series 6 and 7 devices.
 

MANUAL CALL POINTS 
 

KAC indoor call points are available as either semi-flush or surface mounted units. 


Manufactured from modified polyphenylene oxide, indoor call points are sealed to IP44. For use in special environments, a surface mounted waterproof call point, sealed to IP67, is available. 

AIl call point models have an operating temperature range of -30°C to + 70°C and fully comply with BS 5839, Part 2. 

Call Point models WR2072 and WR2072/SR are fitted with normally open switch contacts which close in alarm condition. 

Call point models WR2001, WR2001/SR and WR4001 provide single pole change over switching. Rated up to 250V AC, they can be used in either normally open or normally closed circuits. 

Callpoint models WR3072-680Q (Installer Series) are designed for ease of installation by virtue of terminal backboxes allowing first fix of system cabling. The callpoint unit is provided with flying leads to simplify second fix during commissioning. 

Coloured Call Points 

Only red call points can be used as fire call points. However, all models are also available in white, yellow, blue or green for the operation of ancillary devices, e.g. emergency door release. 


 

FIRE DETECTORS Optical Beam Detectors 

Fireray 1401 and 2000

The Fireray optical beam smoke detector comprises an infra red transmitter which projects a modulated infra-red beam to a receiver unit. The received signal is analysed by a low level controller, which can be positioned up to 250 metres from the receiver and will activate a fire condition should smoke be present. 

With a range of 100 metres and the wide angle beam providing coverage of up to 1,400m2, the Fireray is ideal for any large area application. 

Iinstallation Requirements 

To conform with BS 5839, Part 1, the transmitter and receiver units should be mounted between 600mrn and 800mm below the ceiling height or pitch. A line of sight of 100 metres or less is required between the two units, where the first 10 metres from the transmitter is protected by point detection. A coverage area of 7.5 metres is allowable either side of a central line for lateral detection under a flat ceiling. For pitched ceilings this may be increased by 1% for every degree of pitch up to a maximum of 25%. 

BeamMaster 3 

The Guardall BeamMaster 3 is a combined optical smoke and heat detector. Providing coverage of up to 100 metres, the BeamMaster is ideal for large premises and is particularly suited to long, high buildings. 
 

The detector status can be monitored via a low level indicator which provides LED indication of heat alarm, smoke alarm, fault and normal operating conditions. The indicator panel is powered from the receiver and also features a remote keyswitch reset facility for detector testing. 
 

Connecting Beam Detectors to an Alarm Panel 

In order to interface the Fireray or BeamMaster with a conventional fire panel, zonal wiring must be configured to close the fire relay on an alarm condition. When closed, the fire relay must deliver the required panel switch resistance to the detection circuit. The fault relay should allow zonal wiring to go open circuit in order to activate a zone fault. 
 

 SOUNDERS, BEACONS AND FIRE BELLS 

Fulleon Synchrobell -Roshni, Askari, Squashni & Symphoni 

The Roshni is a high output sounder constructed from durable ABS plastic. Suitable for both 12 and 24v DC systems without the need for adjustment the Roshni is available in red or white and with a deep or shallow base. A mains operated version, 110/240V AC (50Hz), is also available.

The Askari compact has an ultra slim profile and is ideal for locations requiring unobtrusive protection. Available in red or white this sounder can be flush or surface mounted into a standard single-gang box. 

The Squashni is an innovative sounder providing a universal detector platform. The low profile unit can be used as a stand-alone sounder or to allow detectors, beacons, etc., to be installed at the same fixing point. 

Hosiden Besson -Banshee & Bedlam 

Combined Sounder & Strobe Units 

The low profile Banshee sounder features a snap-on front and side or rear cable entry for ease and flexibility of installation. Volume control is fitted as standard to provide up to a 2OdBA reduction in sound output. A high sound output version, the Bedlam, is also available. Both units provide a choice of buzz, fast sweep, slow sweep or continuous alarm sounds. 

The Flashni from Fulleon Synchrobell combines a Roshni sounder with a Xenon beacon to provide a high output sounder/beacon suitable for internal and external locations. The Flashni incorporates a 0 to 2OdBA volume adjustment and is also available as a mains operated version. 

The A V Combined Sounder/Strobe provides both an audio and visual alarm warning with a high profile strobe unit. 

Beacons 

A range of visual indicators to supplement audio alarms in high noise environments. 

Kobishi Fire Bells 

A low consumption Kobishi 6" polarised fire bell is available for internal use, while the 8" fire bell comes complete with an IP65 rated mounting kit. 


 
 

Fulleon Synchrobell Fire Bells 

The Fulleon Synchrobell is available as either a 6" motorised fire bell incorporating a highly efficient rotary centrifugal movement or with solenoid operation. This low current, 24v DC internal fire bell is suitable for both wall and conduit box mounting with installation made simple by the multi-fixing, moulded polycarbonate, base plate. 

Friedland Masterbell 

6" Masterbell is available in 24V DC and 240V AC versions and when installed with additional weatherproof conduit box is suitable fpr external use. Designed for reliability and durability, the Masterbell incorporates a pressed steel bell, a high impact polycarbonate base and a well proven solenoid movement. 
 
 

 
These products and more are to be found on our online Shop
 


 